BVXRT - 401650, MULTI-PURPOSE CERAMIC TILE ADHESIVE (SUPDAT)
- MSDS: BVXRT
- Manufacturer: PRATT AND LAMBERT INC
- Product Name: 401650, MULTI-PURPOSE CERAMIC TILE ADHESIVE (SUPDAT)
- National Stock Number: 8040-00N054487
Product Identification
Product ID:401650, MULTI-PURPOSE CERAMIC TILE ADHESIVE (SUPDAT)
MSDS Date:02/03/1993
FSC:8040
NIIN:00N054487
MSDS Number: BVXRT
Responsible Party
BUFFALO, NY 14240
US
Emergency Phone: 716-873-8000
Info Phone: 800-876-7005
Cage: 77359
Contractor
Telephone: 716-873-6000
Cage: 77359
Ingredients
15%.
CAS: 107-21-1
RTECS: KW2975000
Fraction By Weight: <5%
OSHA PEL 50 PPM (MFR)
ACGIH TLV: 50 PPM, VAPOR, C
EPA Report Quantity: 1 LB
DOT Report Quantity: 1 LB
12 @ 20C.
CAS: 64742-89-8
OSHA PEL N/K
ACGIH TLV: N/K
LESS WATER - 1.55 LB/GAL (186
RTECS: 9999999VO
& MICE WHEN GIVE BY MOUTH AT HIGH CONCS. BECAUSE
RTECS: 9999999ZZ
GLYCOL CAUSES BIRTH DEFECTS IN HUMANS, IT IS
RTECS: 9999999ZZ
CLTHG. WASH AFFECTED AREA W/SOAP & WATER.
RTECS: 9999999ZZ
TOX EFTS OF ETHYLENE GLYCOL, WHEN SWALLOWED ARE
RTECS: 9999999ZZ
ITS EARLY ADMIN MAY BLOCK FORM OF NEPHROTOXIC
RTECS: 9999999ZZ
GIVEN BY IV, AS 5% SOLN IN SODIUM BICARBONATE, @ RATE
RTECS: 9999999ZZ
OF ETHANOL IN BLOOD IS 100 MG/DL. HEMODIALYSIS MAY BE
RTECS: 9999999ZZ
NUMBER OF PATIENTS FOLLOWING POIS W/ETHYLENE GLYCOL.
RTECS: 9999999ZZ
BE NON-CARDIOGENIC IN ORIGIN IN SEVERAL CASES. RESP
RTECS: 9999999ZZ
RESTRICTED VENT AREAS NIOSH/MSHA APPRVD CHEM
RTECS: 9999999ZZ
SPRAYING, NIOSH/MSHA APPRVD MECH PREFILTER MAY ALSO
RTECS: 9999999ZZ
SUPPLIED RESP. IF TLV'S LISTED ARE EXCEEDED USE
RTECS: 9999999ZZ
FACTOR. REFER TO OSHA 29 CFR 1910.134 "RESP PROT" &
RTECS: 9999999ZZ
MAY BE LISTED IN INGS. REFER TO INDUS VENT - MANUAL
RTECS: 9999999ZZ
Hazards
LD50 LC50 Mixture:NONE SPECIFIED BY MANUFACTURER.
Routes of Entry: Inhalation:YES Skin:YES Ingestion:YES
Reports of Carcinogenicity:NTP:NO IARC:NO OSHA:NO
Health Hazards Acute and Chronic:ACUTE:INGEST:CAN CAUSE GI IRRIT, NAUS
& VOMIT. ASPIR OF MATL INTO LUNG MAY CAUSE CHEM PNEUM WHICH CAN BE
FATAL. SWALLOWING OF ETHYLENE GLYCOL MAY CAUSE ABDOM
DISCOMFORT/PAIN, DIZZ, MALAISE, LUMBAR PAI N, OLIGURIA, UREMIA &
CNS DEPRESS. SEV KIDNEY DMG FOLLOWS SWALLOWING OF LG VOLS OF
ETHYLENE GLYCOL. MAY(EFTS OF OVEREXP)
Explanation of Carcinogenicity:NOT RELEVANT
Effects of Overexposure:HLTH HAZ:BE FATAL. INHAL:MAY CAUSE NOSE/THROAT
IRRIT. HIGH CONCS MAY CAUSE ACUTE CNS DEPRESS CHARACT BY HDCHS,
DIZZ, NAUS & CONFUSN. EYE:MAY CAUSE IRRIT. SKIN:MAY CAUSE DEFAT &
IRRIT. CHRONIC:RPTS HAV E ASSOC PRLNG & RPTD OCCUP OVEREXP TO SOLVS
W/PERM BRAIN & NERV SYS DMG. INTENTIONAL MISUSE BY DELIB CONC &
(SUPDAT)
Medical Cond Aggravated by Exposure:NONE SPECIFIED BY MANUFACTURER.
First Aid
First Aid:INGEST:IMMED GIVE 1-2 GLASSES OF WATER & CALL POIS CTL CTR,
HOSPITAL EMER ROOM/MD FOR WAY TO INDUCE VOMIT. (NEVER GIVE ANYTHING
BY MOUTH TO UNCON PERS). INHAL:REMOVE TO FRESH AIR IMMED. IF BRTHG
HAS S TOPPED, GIVE ARTF RESP. KEEP WARM & QUIET. GET MED ATTN
IMMED. EYE:FLUSH W/LG AMTS OF WATER, LIFTING UPPER & LOWER LIDS
OCCAS. CONTINUE FOR AT LST 15 MINS. GET MED ATTN. SKIN:REMOVE
CONTAM (ING 6)
Fire Fighting
Lower Limits:SEE ING 1
Upper Limits:SEE ING 1
Extinguishing Media:USE NFPA CLASS B FIRE EXTINGS (CARBON DIOXIDE, ALL
PURPOSE DRY CHEM/ALCOHOL FOAM) DESIGNED TO EXTING FLAMM LIQ
(SUPDAT)
Fire Fighting Procedures:USE NIOSH/MSHA APPRVD SCBA & FULL PROT EQUIP .
WATER MAY BE INEFT, BUT MAY BE USED TO COOL EXPOS CNTNRS TO PVNT
PRESS BUILD-UP & POSS AUTO-IGNIT/ (SUPDAT)
Unusual Fire/Explosion Hazard:NONE SPECIFIED BY MANUFACTURER.
Accidental Release
Spill Release Procedures:USE A PROPERLY FITTED, NIOSH/MSHA APPROVED
CHEMICAL CARTRIDGE RESPIRATOR OR A PROPERLY FITTED, NIOSH/MSHA
APPROVED AIR-SUPPLIED RESPIRATOR FOR A LARGE SPILL IN A CONFINED
AREA.
Neutralizing Agent:NONE SPECIFIED BY MANUFACTURER.
Handling
Handling and Storage Precautions:DO NOT STORE >115F(46C). STORE LARGE
QUANTITIES IN COMPLIANCE W/OSHA 29 CFR 1910.106. DO NOT TAKE
INTERNALLY. CLOSE CONTAINER AFTER EACH USE.
Other Precautions:KEEP AWAY FROM CHILDREN. EMPTY CONTAINERS MUST NOT BE
WASHED & RE-USED FOR ANY PURPOSE. NEVER USE PRESSURE TO EMPTY. DRUM
IS NOT A PRESSURE VESSEL.
Exposure Controls
Respiratory Protection:PROPER SELECTION OF RESP PROT DEPENDS UPON MANY
FACTORS INCL DURATION/LEVEL OF EXPOS & CNDTNS OF USE. IN GEN, EXPOS
TO ORG CHEMS SUCH AS THOSE CNTND IN THIS PROD MAY NOT REQ USE OF
RESP PROT IF USED I N WELL VENTILATED AREAS. IN (ING 13)
Ventilation:PROVIDE LOC EXHST VENT IN SUFFICIENT VOL & PATTERN SO AS TO
MAINTAIN EXPOS BELOW NUISANCE DUST LIMS & PELS WHICH(ING 17)
Protective Gloves:SOLVENT IMPERMEABLE GLOVES.
Eye Protection:ANSI APPROVED CHEM WORKERS GOGGS .
Other Protective Equipment:NOT LIKELY TO BE NEEDED.
Work Hygienic Practices:NONE SPECIFIED BY MANUFACTURER.
Supplemental Safety and Health
MFR'S TRADE NAME/PART NO:(WALL & FLOOR). EXTING MEDIA:FIRES. POLYMER
FOAM IS PREF FOR LG FIRES. FIRE FIGHT PROC:EXPLO WHEN EXPOS TO
EXTREME HEAT. IF WATER IS USED, FOG NOZZ ARE PREF. EFTS OF
OVEREXP:I NHALING CONTENTS MAY BE HARMFUL/FATAL. ETHYLENE GLYCOL
HAS BEEN SHOWN TO PRDCE DOSE-RELATED BIRTH DEFECTS IN RATS(ING 4)
Chemical Properties
HCC:N1
Boiling Pt:B.P. Text:>162F,>72C
Vapor Pres:SEE INGS
Vapor Density:HVR/AIR
Spec Gravity:1.2
Evaporation Rate & Reference:SLOWER THAN DIETHYL ETHER
Appearance and Odor:NONE SPECIFIED BY MANUFACTURER.
Percent Volatiles by Volume:54
Stability
Stability Indicator/Materials to Avoid:YES
STRONG ACIDS OR ALKALINE MATERIALS.
Stability Condition to Avoid:NONE KNOWN.
Hazardous Decomposition Products:BURNING, INCLUDING WHEN HEATED BY
WELDING/CUTTING, WILL PRODUCE SMOKE, CARBON MONOXIDE & CARBON
DIOXIDE.
Disposal
Waste Disposal Methods:DISPOSE I/A/W FEDERAL, STATE & LOCAL LAWS. AS
PRODUCED, THIS PRODUCT IS NOT A WASTE. IF DISCARDED AS IS, IT IS
NOT CLASSIFIED AS A HAZARDOUS WASTE UNDER RCRA.
Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.